1.
AANA J ; 90(1): 50-57, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35076384

RESUMO

With a brief summary of selected literature identified by a multidisciplinary panel of subject matter experts, the authors share their experience with the development of an institutional perioperative pain management guideline for patients on maintenance medication for addiction treatment (MAT), stressing the importance of perioperative continuation of opioid agonists such as methadone and partial agonists such as buprenorphine; and the discontinuation of opioid antagonists, such as naltrexone. The authors' protocol is appended as an example of a standardized approach to perioperative management of patients on MAT.


Assuntos
Buprenorfina , Transtornos Relacionados ao Uso de Opioides , Analgésicos Opioides/uso terapêutico , Buprenorfina/uso terapêutico , Humanos , Metadona/uso terapêutico , Naltrexona/uso terapêutico , Tratamento de Substituição de Opiáceos , Transtornos Relacionados ao Uso de Opioides/tratamento farmacológico , Transtornos Relacionados ao Uso de Opioides/prevenção & controle
2.
Laryngoscope ; 131(12): 2773-2781, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34338303

RESUMO

OBJECTIVES/HYPOTHESIS: The objective of this study was to compare ventilation techniques utilized in microlaryngeal surgery. STUDY DESIGN: Retrospective cohort study. METHODS: Two-hundred surgeries performed from May 1, 2018 to March 1, 2020 and stratified as intubated, intermittently intubated (AAIV) or apneic. Patient demographics, comorbidities, anesthetic agents, intraoperative parameters/events, and complications were studied and compared across the three groups using inferential analyses. RESULTS: Median body mass index in the AAIV group was significantly higher (33 vs. 29; P = .0117). Median oxygen nadirs were lower in AAIV cases (81% vs. 91-92%) while CO2 peak measurements were lower (33 mmHg vs. 48 mmHg) in the fully apneic cohort which were significantly shorter cases (P < .0001). CO2 peak measurements were comparable between AAIV and intubated cohorts (median 48.5 mmHg vs. 48.0 mmHg). Median apnea times were significantly prolonged by 2-5.5 minutes using nasal cannula and THRIVE/Optiflow in fully apneic cases when compared to no supplementary oxygenation (P = .0013). Systolic blood pressures following insertion of laryngoscope were higher (159.5 vs. 145 mmHg) and postoperative diastolic pressures were lower (68.5 vs. 76.5 mmHg) in fully apneic cases than intubated cases. No differences existed between frequencies of complications. CONCLUSIONS: This study compares intubated, intermittently apneic, and fully apneic surgeries. No statistically significant differences were noted in comorbid conditions. While intraoperative hemodynamic fluctuations were more pronounced in the fully apneic cohort, and oxygenation distributions were lower in the AAIV cohort, no significant differences existed between events and complications. Apneic techniques are as safe and effective as traditional intubation. LEVEL OF EVIDENCE: 4 Laryngoscope, 131:2773-2781, 2021.


Assuntos
Cânula/efeitos adversos , Complicações Intraoperatórias/epidemiologia , Laringe/cirurgia , Microcirurgia/efeitos adversos , Respiração Artificial/efeitos adversos , Adulto , Idoso , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Complicações Intraoperatórias/etiologia , Masculino , Pessoa de Meia-Idade , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Respiração Artificial/estatística & dados numéricos , Estudos Retrospectivos
3.
AANA J ; 73(2): 111-3, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15835830

RESUMO

The electromyographic endotracheal tube (EMG-ETT) is a relatively new tool used to measure integrity of the vocal cord structures during surgery. We describe a case in which an EMG-ETT was inserted for the operative period but not replaced with an ETT during the immediate postoperative period. Intensive care unit nurses had difficulty suctioning the EMG-ETT. The patient was not provided the pulmonary toilet necessary until the EMG-ETT was removed and replaced with a regular ETT. The purpose of this article is to make anesthesia providers aware that when mechanical ventilation is required during the postoperative period, the EMG-ETT should be removed and replaced with a regular ETT to facilitate pulmonary toilet.


Assuntos
Eletromiografia/efeitos adversos , Eletromiografia/instrumentação , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/instrumentação , Sucção , Idoso , Neoplasias Encefálicas/cirurgia , Craniotomia , Eletrodos , Eletromiografia/enfermagem , Desenho de Equipamento , Falha de Equipamento , Potenciais Somatossensoriais Evocados , Humanos , Intubação Intratraqueal/enfermagem , Masculino , Monitorização Intraoperatória , Respiração Artificial , Sucção/instrumentação , Sucção/enfermagem , Prega Vocal/fisiologia